    采用热分解法制备了Ti/SnO2电极,以苯酚为目标污染物,研究苯酚废水在电极上电解的最佳条件、电解一定时间后的电压以及电极的寿命。结果表明,在电流密度为190 A/m2和pH值为2的条件下,苯酚溶液初始质量浓度为70 mg/L,电解350 min后,苯酚和COD的降解效率最高,分别为96.80%和40%,苯酚被降解为中间产物,没有被彻底矿化为CO2和H2O,此时的电压为8 V。在25℃,0.5 mol/L的H2SO4水溶液中、恒流500 A/m2条件下对电极的寿命测试,电极寿命仅仅为8 h,寿命较短。

    Abstract:

    Ti/SnO2 electrode was prepared by thermal decomposition method. With phenol taken as the goal pollutant, the optimum conditions of electrolysis of phenol wastewater on electrode were studied together with the voltage after electrolysis for a certain time and the lifetime of electrode. The results show that the initial mass concentration of phenol solution was 70 mg/L at the current density of 190 A/m2 and pH value of 2. After 350 minutes of electrolysis, the degradation efficiencies of phenol and COD were the highest, 96. 80% and 40%, respectively. Phenol was degraded into intermediate product, which was not completely mineralized to CO2 and H2O, and the voltage was 8V. The lifetime of the electrode was measured at 25℃, 0. 5 mol/L H2SO4 solution and 500 A/m2 constant flow. The electrode life was only 8 hours and the life was short.

    参考文献
    相似文献
    引证文献
引用本文

李艳红,王三反,李志伟. Ti/SnO2电极在苯酚废水降解中的应用[J].水资源保护,2017,33(6):92-95.(LI Yanhong, WANG Sanfan, LI Zhiwei. Application of Ti/SnO2 electrode in degradation of phenol wastewater[J]. Water Resources Protection,2017,33(6):92-95.(in Chinese))

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2017-01-06
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2017-11-24
  • 出版日期: