Calculation of stress intensity factor of steam generator safety-end welded joint
CSTR:
Author:
Affiliation:

Clc Number:

TU122

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The weak form of the extended finite element method(XFEM)with the initial stress field was derived, and was used to numerically simulate the crack in a weld-induced residual stress field. A more accurate stress intensity factor(SIF)was obtained with the interaction integral method. Based on this, the variation of SIF of steam generator safety-end dissimilar metal joints with the crack depth in the weld-induced residual stress field was analyzed. The results show that SIF increases first and then decreases with the continuous propagation of the crack inside the welded joint, indicating that the resistance of a material against crack propagation increases first and then decreases. The method of exerting an initial stress field utilizes the advantage of XFEM in simulation of crack propagation, and avoids the repetitive computation induced by grid updating.

    Reference
    Related
    Cited by
Get Citation

朱保印,夏晓舟,何铮,等.蒸汽发生器安全端焊接接头应力强度因子计算[J].河海大学学报(自然科学版),2017,45(3):243-248.(ZHU Baoyin, XIA Xiaozhou, HE Zheng, et al. Calculation of stress intensity factor of steam generator safety-end welded joint[J]. Journal of Hohai University (Natural Sciences),2017,45(3):243-248.(in Chinese))