高密度电法在堤坝渗漏监测中的模拟及应用
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

P631.3

基金项目:

江西省教育厅科技项目(GJJ161119,GJJ171006);深圳市深水水务咨询有限公司项目(0101-05190016)


Modeling and application of high-density electrical method in dam leakage monitoring
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 文章评论
    摘要:

    在堤坝渗漏监测中,由于影响因素复杂,资料解释存在一定的干扰。通过建立两组典型的堤坝渗漏地电模型,结合正演模拟分析其响应特征,将视电阻率拟断面图和反演结果结合分析,可以排除一些假异常干扰,提高对目标体的识别。在对某大坝的渗流异常监测中,结合实测资料拟断面图和反演结果,通过对低阻异常体的连续追踪,推断出异常渗流的原因及渗漏通道的位置,可为下一步的工程处理提供依据。

    Abstract:

    In dam leakage monitoring, due to the complexity of influencing factors, certain interference exists for data interpretation. Two groups of typical geoelectric models of dam leakage were established, and their response characteristics were analyzed by forward modeling. The combination analysis of apparent resistivity pseudo sections and inversion results can eliminate some false anomaly interference and improve the recognition of target. In the anomaly seepage monitoring of a dam, combined with the measured data and inversion results, through continuous tracking of the low resistance abnormal body, the causes of abnormal seepage and the location of the leakage passage were deduced, providing basis for engineering treatment in the next step.

    参考文献
    相似文献
    引证文献
引用本文

刘晓,彭友文,袁志辉,等.高密度电法在堤坝渗漏监测中的模拟及应用[J].水利水电科技进展,2021,41(5):71-75.(LIU Xiao, PENG Youwen, YUAN Zhihui, et al. Modeling and application of high-density electrical method in dam leakage monitoring[J]. Advances in Science and Technology of Water Resources,2021,41(5):71-75.(in Chinese))

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2021-10-16
  • 出版日期: