渡槽排架结构环境激励模态试验
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TV332

基金项目:

国家重点研发计划(2016YFC0401807)


Modal test of aqueduct bent structures based on ambient excitation
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 文章评论
    摘要:

    为获得渡槽排架结构动力特性,开展渡槽排架单向单输入多输出(SIMO)法、双向多输入多输出(MIMO)法环境激励模态试验,选用增强频域分解法识别纵向、横向、双向模态参数。结果表明,SIMO法纵向模态绝大多数谱峰明显、识别效果较好,纵向模态比横向模态丰富;MIMO法纵向或以纵向为主的谱峰大多数明显,横向或以横向为主、双向模态除双向第2阶(即横向第1阶)谱峰明显外,其他较小,甚至未能识别;排架柱以弯曲振动为主,纵向低阶、高阶模态横梁分别以平动或转动刚体振动、弯曲振动为主,横向模态横梁为平动或不动刚体振动;两种方法识别出的模态频率误差较小,SIMO法结果更为可靠,尤其是低阶模态。从低阶识别精度、试验工作量及操作便捷性而言,排架结构环境激励模态试验选择单向SIMO法优于双向MIMO法。

    Abstract:

    Ambient excitation modal tests of one-way SIMO(single input multiple output)method and two-way MIMO(multiple input multiple output)method were carried out to obtain the dynamic characteristics of aqueduct bent structures. Longitudinal, transverse and bidirectional modal parameters were identified by enhanced frequency domain decomposition. The results show that most spectrum peaks of longitudinal modes are obvious with better identification results, and the longitudinal modes are more abundant than transverse ones by SIMO method. Most spectrum peaks of longitudinal or mainly longitudinal modes are also obvious by MIMO method. However, spectrum peaks of transverse modes or mainly transverse modes, bidirectional modes are small and some are difficult to be identified except for the second bidirectional order mode, i. e. the first transverse order mode. The column is identified with bending vibration. The beam is identified with rigid body vibration of translation or rotation for longitudinal low-order modal shapes, while it is characterized with bending vibration for high-order modes. For transverse modal shapes, the beam is identified with rigid body vibration of translation or immovability. The error of modal frequency identified by SIMO and MIMO methods is small. The results by SIMO method are more reliable, especially for low-order modes. Therefore, in the aspects of low-order modes identification accuracy, test workload and operation convenience, one-way SIMO method is better than two-way MIMO method for bent structure modal test.

    参考文献
    相似文献
    引证文献
引用本文

顾培英,刘冬梅,邓昌,等.渡槽排架结构环境激励模态试验[J].水利水电科技进展,2019,39(4):56-63.(GU Peiying, LIU Dongmei, DENG Chang, et al. Modal test of aqueduct bent structures based on ambient excitation[J]. Advances in Science and Technology of Water Resources,2019,39(4):56-63.(in Chinese))

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2019-07-24
  • 出版日期: