    In dam leakage monitoring, due to the complexity of influencing factors, certain interference exists for data interpretation. Two groups of typical geoelectric models of dam leakage were established, and their response characteristics were analyzed by forward modeling. The combination analysis of apparent resistivity pseudo sections and inversion results can eliminate some false anomaly interference and improve the recognition of target. In the anomaly seepage monitoring of a dam, combined with the measured data and inversion results, through continuous tracking of the low resistance abnormal body, the causes of abnormal seepage and the location of the leakage passage were deduced, providing basis for engineering treatment in the next step.

    Reference
    Related
    Cited by
Get Citation

刘晓,彭友文,袁志辉,等.高密度电法在堤坝渗漏监测中的模拟及应用[J].水利水电科技进展,2021,41(5):71-75.(LIU Xiao, PENG Youwen, YUAN Zhihui, et al. Modeling and application of high-density electrical method in dam leakage monitoring[J]. Advances in Science and Technology of Water Resources,2021,41(5):71-75.(in Chinese))