The effect of node type selection for catchment division on urban stormwater simulation
CSTR:
Author:
Affiliation:

Clc Number:

P333

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The storm drainage system model of Xincheng Park in Guangming New District of Shenzhen was set up based on InfoWorks ICM model. In this study the catchment area was divided respectively according to manhole and gully, and its effect on flow simulation results of park outlet was analyzed. The results showed that the selection of node-type had no obvious effect on peak flow simulation result in the condition of light or medium rainfall, while for storm or heavy rainfall the selection of node-type had great influence on peak flow. Compared to catchment division based on manhole, runoff-yielding time producing was delayed by dividing the catchment area based on gully. Therefore, research goal, regional scale and rainfall characteristics should be considered in the process of modeling to reasonably divide the catchment area.

    Reference
    Related
    Cited by
Get Citation

宋瑞宁,宫永伟,李俊奇,等.汇水区节点选取对城市雨洪模拟结果的影响[J].水利水电科技进展,2015,35(3):75-79.(SONG Ruining, GONG Yongwei, LI Junqi, et al. The effect of node type selection for catchment division on urban stormwater simulation[J]. Advances in Science and Technology of Water Resources,2015,35(3):75-79.(in Chinese))